Skip to main navigation Skip to search Skip to main content

Multiplex Assays in Allergy Diagnosis: Allergy Explorer 2 versus ImmunoCAP ISAC E112i

  • Hannes Nösslinger
  • , Ewald Mair
  • , Gertie J Oostingh
  • , Verena Ahlgrimm-Siess
  • , Anna Ringauf
  • , Roland Lang
  • Hospital of Merano (SABES-ASDAA)
  • Registered pediatrician (SABES-ASDAA)
  • Department of Ophthalmology and Optometry, SALK, University Hospital of the Paracelsus Medical University Salzburg
  • MacroArray Diagnostics (MADx)

Research output: Contribution to journalArticlepeer-review

Abstract

ImmunoCAP ISAC E112i (ISAC) and Allergy Explorer 2 (ALEX 2) detect specific immunoglobulin E (IgE) reactivity. Both multiplex assays contain molecular allergens and ALEX 2 additionally includes allergen extracts and inhibitors that block the binding of IgE to cross-reacting carbohydrate determinants (CCDs). This study aimed to compare the performance of ISAC and ALEX 2 by determining the IgE reactivity against allergen extracts and/or allergen components and by using qualitative, semiquantitative, and quantitative analyses of all comparable allergen components in sera from 216 participants recruited in South Tyrol/Italy. For extract sensitization in ALEX 2, the analysis revealed negative corresponding allergen components in 18.4% and at least one positive corresponding allergen component in 81.6% of all cases. For ISAC, the corresponding results were 23.5% and 76.5% of cases, respectively. The ALEX 2 CCD inhibitor eliminated CCD-positive signals detected by ISAC in 88.5% of cases. Based on sensitization values of 0.3-14.9 ISU or kU A/L, there was good agreement between ALEX 2 and ISAC, although ALEX 2 showed higher values than ISAC. The addition of allergen-extract tests in ALEX 2 resulted in the detection of more sensitizations than with corresponding allergen components alone. In the range of <15 ISU or kU A/L, ALEX 2 may be more effective in detecting sensitizations.

Original languageEnglish
Pages (from-to)976
Number of pages1
JournalDiagnostics
Volume14
Issue number10
DOIs
Publication statusPublished - 8 May 2024

Classification according to Österreichische Systematik der Wissenschaftszweige (ÖFOS 2012)

  • 303012 Health sciences

Applied Research Level (ARL)

  • Not applicable

Research focus/foci

  • Applied Health Innovation

Fingerprint

Dive into the research topics of 'Multiplex Assays in Allergy Diagnosis: Allergy Explorer 2 versus ImmunoCAP ISAC E112i'. Together they form a unique fingerprint.

Cite this